Equipment of laboratory of physics of interaction of ion beams with materials
Accelerating complex for study of helium and hydrogen behavior in conditions of generation of radiation defects
![ESU-2 ESU-2](images/KIPT img/14-20Eqv_1.jpg)
Parameters of irradiation system “ESU-2”
- The range of smooth regulation of beam energy, keV - 200-2000
- Maximum of beam current, mkA - 10
- The range of current regulation, mkA - 0,1-10
- The kind of accelerated ions inert from He to Xe, chemically active from hydrogen to nitrogen
![accelerating complex accelerating complex](images/KIPT img/14-20Eqv_2.jpg)
- Simultaneous implantation of helium and hydrogen is realized by two irradiating assemblies which provide the possibility to vary the particle energy in the range 3…50 keV.;
- Irradiation of specimens and investigation by nuclear-physical methods is performed in one experimental chamber.ss
Accelerating installation with energy of particles to 0,1 MeV
Two-beam accelerating installation “ANT”
![assembly ANT assembly ANT](images/KIPT img/14-20Eqv_3.jpg)
Accelerating complex where two high-voltage accelerators of the Kokroft and Uolton type with aligned beams of ions are assembled on one bed-support (M1=1…14, M2=1…40a.e.m.) with energy 20 and 100 keV, respectively.
Beam I – E=1-20 keV; 15 µA;
Beam II – E=15-100 keV; 10 µA;
(hydrogen, deuterium, helium, nitrogen, oxygen)
Multipurpose experimental assembly “SKIF”
![assembly SKIF assembly SKIF](images/KIPT img/14-20Eqv_5.jpg)
(gas ions with E=20-100 keV)
The assembly represents the irradiating facility; target chamber is placed outlet the irradiating facility and is completed with detector (or several detectors) for measurement of partial pressure of gases released of irradiated target on its heating.